{"product_id":"pv03500-semi-pv35-specification-for-horizontal-communication-between-equipment-for-photovoltaic-fabrication-system","title":"PV03500 - SEMI PV35 - Specification for Horizontal Communication Between Equipment for Photovoltaic Fabrication System","description":"\u003cp dir=\"ltr\" align=\"justify\"\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003e\u003cb\u003eNOTICE:\u003c\/b\u003e This Document is no longer supported by the global\ntechnical committee. It has been replaced by SEMI A1.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003e \u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eThe purpose of this Standard is to provide a specification\nfor communication between adjacent equipment in material flow (hereinafter referred\nto as horizontal communication [HC]) to be used for photovoltaic fabrication\nsystem or similar ones (equipment here includes process equipment, metrology\nequipment, transport equipment and clustered one of those, etc.).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003e \u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eThe purpose of this Standard is also to provide HC to\nperform both ‘Material and associated data transfer’ and ‘General purpose data\nexchange’ without factory host assistance.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003e \u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eThe purpose of this Standard is also to provide HC\nspecification to cover the following cases based on a common concept.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eVarious material transfer types (such as Single Substrate\nand Multiple Substrate with\/without Carrier).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eVarious material flow type combinations (such as\nUni-Direction, Alternate-Direction, Bi-Direction and multiple set and\/or combination\nof them).\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003e \u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eThe purpose of this Standard is also to provide HC\nspecification that is compatible with various line connection topologies (such\nas Branch and Merge).\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003e \u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eThe purpose of this Standard is also to provide scalable\nspecification to support sufficient HC functionality for lower implementation cost.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003e \u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eSubordinate Standard (included)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eSEMI PV35.1-0215 - Specification for Horizontal\nCommunication Between Equipment for Photovoltaic Fabrication System\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003e \u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003e\u003cb\u003eReferenced SEMI Standards\u003c\/b\u003e (purchase separately)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eNone.\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003e \u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003e\u003cb\u003eRevision History\u003c\/b\u003e\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eSEMI PV35-0215 (technical revision) - Replaced by SEMI A1\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eSEMI PV35-1214 (technical revision)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eSEMI PV35-0414 (technical revision)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eSEMI PV35-0114 (designation update)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eSEMI PV35-1012 (first published)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003e \u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eSEMI PV35.1-0215 (technical revision) - Replaced by SEMI A1.1\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style='font-size:10.0pt;line-height:107%;font-family:\n\"Arial\",sans-serif'\u003eSEMI PV35.1-1214 (technical revision)\u003co:p\u003e\u003c\/o:p\u003e\u003c\/span\u003e\u003c\/p\u003e\n\n\u003cp dir=\"ltr\" align=\"justify\"\u003e\u003cspan style=\"font-family: Arial, sans-serif; font-size: 10pt;\"\u003eSEMI PV35.1-0114 (first published)\u003c\/span\u003e \u003c\/p\u003e \u003cp dir=\"ltr\" align=\"justify\"\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"semi.org","offers":[{"title":"SEMI PV35-0215 - Replaced","offer_id":40234370203715,"sku":"14644","price":31900.0,"currency_code":"JPY","in_stock":true},{"title":"SEMI PV35-1214 - Superseded","offer_id":40234370236483,"sku":"12771","price":31900.0,"currency_code":"JPY","in_stock":true},{"title":"SEMI PV35-0414 - Superseded","offer_id":40234370269251,"sku":"12769","price":31900.0,"currency_code":"JPY","in_stock":true},{"title":"SEMI PV35-0114 - Superseded","offer_id":40234370302019,"sku":"12768","price":31900.0,"currency_code":"JPY","in_stock":true},{"title":"SEMI PV35-1012 - Superseded","offer_id":40234370334787,"sku":"12770","price":31900.0,"currency_code":"JPY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0567\/3402\/3747\/files\/PVVolume_9fa7ad23-b85c-40c7-a3c1-d5a869de0b6b.png?v=1776701868","url":"https:\/\/store-dev2.semi.org\/en-jp\/products\/pv03500-semi-pv35-specification-for-horizontal-communication-between-equipment-for-photovoltaic-fabrication-system","provider":"SEMI Dev 2","version":"1.0","type":"link"}